首頁 > 軟體

Linux 硬碟故障案例分享

2020-06-16 17:53:16

本文主要分享下Linux伺服器中硬碟發生故障後/var/log/messages 和/var/log/mcelog中會出現的具體紀錄檔以及對應的修復方法,隨著案例的不斷增多和豐富,最後我會歸納形成自動化指令碼。

當然其中會有很多硬碟有物理壞軌,需要更換,這種就需要硬碟供應商去更換了,此處不在本文討論範圍。

伺服器型號:

HP SE1170s

硬碟型號:

MB2000EAZNL

故障1:

Jul 17 00:46:34 xxxxxxxxxxxxxx kernel: [8384801.159283] EXT4-fs (sdl1): warning: mounting fs with errors, running e2fsck is recommended

Jul 17 00:50:00 xxxxxxxxxxxxxx kernel: [8385006.016500] sd 6:0:6:0: [sdl] Sense Key : Medium Error [current]

Jul 17 00:50:00 xxxxxxxxxxxxxx kernel: [8385006.016508] sd 6:0:6:0: [sdl] Add. Sense: Unrecovered read error

Jul 17 00:50:00 xxxxxxxxxxxxxx kernel: [8385006.016524] Buffer I/O error on device sdl1, logical block 1415594116

Jul 17 00:50:00 xxxxxxxxxxxxxx kernel: [8385006.095561] Buffer I/O error on device sdl1, logical block 1415594117

故障解決:

#e2fsck /dev/sdl1

若壞的block無法修復,則需要用fdisk格式化硬碟:

#fdisk /dev/sdl

#d

#n

#p

#Enter

#Enter

#w

用ext4檔案系統格式化磁碟:

#mkfs.ext4 /dev/sdl1

把格式化好的硬碟mount回來:

#mount -L /Hadoop07 /hadoop/7 -t ext4 -o defaults,noatime,nodiratime,noauto

若幾天後發現/var/log/messages裡面有最新的/dev/sdl的錯誤紀錄檔,則表明此硬碟需要更換了,這時可以先禁掉這塊盤所掛在目錄的讀寫功能,在此之前你可以先把裡面的資料拷貝出來:

#chmod 0 /hadoop07

本文永久更新連結地址http://www.linuxidc.com/Linux/2015-09/122950.htm